ADA Access Consultants

ADA Surveys of Physical & Website Environments

ADA Compliance Checklist for Businesses:
Parking, Entrances, Restrooms and More

An ADA compliance checklist is a walk-through list of the measurable elements the 2010 ADA Standards for Accessible Design require at a place of public accommodation, organized in the order the Department of Justice tells businesses to fix barriers: the approach and entrance first, then the areas where goods and services are provided, then restrooms, then everything else [28 CFR 36.304(c)]. This page is that list, written by licensed CASp inspectors, with the exact numbers we measure against on every inspection.

Use it to self-check an existing building before a lawsuit does it for you. Every item below cites the ADA Standards section and, where California is stricter, the California Building Code (CBC) Chapter 11B section. If you want the short version: these ten violations account for most of what we find.

CASp inspector measuring a ramp handrail with a tape during an ADA compliance checklist walk-through
Every item on this checklist is a measurement. A tape measure and a 24-inch digital level cover most of it.

How to use this ADA checklist

Walk the property the way a customer in a wheelchair would: park, cross the lot, enter, reach the counter, use the restroom, leave. Check each box only when you have measured the element, not when it “looks fine.” Slopes in particular cannot be judged by eye; a parking space that reads 2.5% on a level is a violation at 1:48 (2.08%).

The DOJ’s barrier-removal priorities [28 CFR 36.304(c)] set the order of the sections below:

  1. Accessible approach and entrance (parking, route, doors)
  2. Access to goods and services (counters, aisles, seating, reach ranges)
  3. Restrooms
  4. Everything else (drinking fountains, signage, protruding objects)

Existing buildings do not get a pass. Under Title III, barriers must be removed wherever that is readily achievable, and in California an ADA violation is also an Unruh Act violation with a $4,000 minimum per occasion [Civ. Code §51(f), §52(a)].

1. Parking checklist

Parking is the first thing a plaintiff’s investigator photographs from the street, and it is where most ADA lawsuits start. Count your total spaces first, then check each item.

☐ItemADA requirementCalifornia (CBC 11B)
☐Number of accessible spaces1–25 spaces: 1; 26–50: 2; 51–75: 3; 76–100: 4; 101–150: 5; 151–200: 6; 201–300: 7; 301–400: 8; 401–500: 9; 501–1,000: 2%; over 1,000: 20 + 1 per 100 [Table 208.2]Same table [11B-208.2]
☐Van spaces1 of every 6 accessible spaces (or fraction) [§208.2.4]Same
☐Space widthCar 96″ min; van 132″ min (or 96″ with a 96″ aisle) [§502.2]Car 108″; van 144″ (or 108″ with 96″ aisle); 216″ long [11B-502.2]
☐Access aisle60″ wide min, full length of space, marked [§502.3]60″; “NO PARKING” in 12″ white letters [11B-502.3.3]
☐Slope of space and aisle1:48 max (2.08%) in every direction [§502.4]Same
☐Vertical clearance at van space and route98″ min [§502.5]Same
☐SignISA symbol; “van accessible” at van spaces; bottom of sign 60″ min above ground [§502.6]Plus “Minimum Fine $250″ sign, 36″ × 36” ISA painted in the space, and a tow-away sign at each lot entrance [11B-502.6.2, 11B-502.6.4.1, 11B-502.8]
☐LocationOn the shortest accessible route to the accessible entrance [§208.3.1]Same
ADA parking space width diagram: 132 inch van space, 60 inch access aisle, 96 inch car space
Federal minimums shown. California requires 108″ car spaces, 144″ van spaces and 216″ length, so a lot striped to 96″ fails a CASp inspection.

Related: parking lot striping for ADA compliance.

2. Accessible route and entrance checklist

An accessible route must connect the accessible parking, the public sidewalk and any transit stop to the accessible entrance, and then to every public area inside [§206.2]. Measure it end to end.

Exterior route, curb ramps and ramps

☐ItemADA requirementCalifornia (CBC 11B)
☐Route width36″ min; 32″ for segments up to 24″ long [§403.5.1]48″ min for exterior walks and sidewalks [11B-403.5.1]
☐Running slope of walk1:20 max (5%); steeper is a ramp [§403.3]Same
☐Cross slope1:48 max [§403.3]Same
☐Changes in level¼” max vertical; ¼”–½” beveled 1:2; over ½” must be ramped [§303]Same
☐Openings and gratingsNo opening passes a ½” sphere; long dimension perpendicular to travel [§302.3]Same
☐Ramp slope1:12 max (8.33%) [§405.2]Same, with no 1:10 or 1:8 exceptions for existing sites
☐Ramp width36″ min between handrails [§405.5]48″ min [11B-405.5]
☐Ramp rise and landings30″ max rise per run; landings 60″ long [§405.6, §405.7]Top landing 60″ × 60″; bottom landing 72″ in the direction of travel [11B-405.7]
☐Ramp handrailsBoth sides where rise exceeds 6″; 34″–38″ high; 12″ horizontal extensions [§405.8, §505.4, §505.10]Same
☐Edge protectionCurb, barrier or extended surface so a 4″ sphere cannot pass [§405.9]Same [11B-405.9.2]
☐Curb ramp flares1:10 max [§406.3]Same
☐Detectable warningsTruncated domes where required (transit platforms under the 2010 Standards) [§705]Required at curb ramps and vehicular crossings; yellow, domes 2.3″–2.4″ apart, 36″ deep at curb ramps [11B-705.1.1, 11B-705.1.2.2]
Accessible sidewalk route along a storefront, checked for width, slope and cross slope
California requires 48-inch sidewalks and walks, not the federal 36 inches.

Slope rules in depth: ADA wheelchair ramp requirements and ADA sidewalk requirements.

Entrance and doors

☐ItemADA requirementCalifornia (CBC 11B)
☐Accessible entrancesAt least 60% of public entrances [§206.4.1]All entrances [11B-206.4.1]
☐Clear opening width32″ min with the door open 90° [§404.2.3]Same
☐Maneuvering clearance, front approachPull side 60″ deep + 18″ beside the latch; push side 48″ deep (+12″ if closer and latch) [§404.2.4]Same
☐Threshold½” max; ¾” at existing doors, beveled [§404.2.5]Same
☐HardwareLever, push or loop; no grasping, pinching or twisting; 34″–48″ high [§404.2.7, §309.4]34″–44″ high [11B-404.2.7]
☐Opening force5 lbf max for interior hinged doors [§404.2.9]5 lbf interior and exterior; fire doors 15 lbf max [11B-404.2.9]
☐Closing speed5 seconds min from 90° to 12° [§404.2.8.1]Same
☐Smooth kick plateBottom 10″ of push side smooth [§404.2.10]Same
ADA door width requirements chart showing 32 inch clear opening measured at 90 degrees
Clear width is measured from the face of the door to the stop with the door open 90°, not the frame width.

Door details: ADA door requirements and ADA clearance requirements.

3. Goods and services checklist: counters, aisles, seating, reach

Once inside, the question is whether a wheelchair user can get to and use what everyone else uses. Measure clear floor space (30″ × 48″) at every element a customer operates [§305.3].

☐ItemADA requirementCalifornia (CBC 11B)
☐Interior route width36″ min [§403.5.1]44″ in corridors serving an occupant load of 10 or more [11B-403.5.1]
☐Turning space60″ circle or T-shape in each room [§304.3]Same
☐Sales and service countersA 36″ long section no higher than 36″ (parallel approach), or 30″ long at 36″ max with knee space (forward approach) [§904.4]Same
☐Check-out aislesCounter 38″ max; edge protection 2″ max above the counter [§904.3.2]Same
☐Dining and work surfaces5% accessible; top 28″–34″ high; knee clearance 27″ high, 30″ wide, at least 17″ deep [§226, §902, §306]Same; clear floor space may not overlap the accessible route [11B-902.2]
☐Reach rangesOperable parts 15″–48″ above the floor, unobstructed [§308]Same
☐Operable partsOne hand, 5 lbf max, no tight grasping [§309.4]Same
☐Protruding objectsObjects 27″–80″ above the floor may stick out 4″ max from a wall; 80″ headroom [§307]Same
☐Self-service shelves and displaysWithin reach range; aisles 36″ [§308, §403]Same
ADA service counter diagram: 36 inch maximum height over a 36 inch minimum length
A 36-inch-long section at 36 inches or lower is the most common counter fix, and one of the cheapest.

Related: ADA compliant service counters, ADA reach range and ADA table requirements.

4. Restroom checklist

Restrooms generate more inspection findings than any other room because 20 or more measurements have to be right at once. The items below are the ones that fail most often. The full list is in our ADA bathroom requirements guide.

☐ItemADA requirementCalifornia (CBC 11B)
☐Door and signage32″ clear; tactile sign on the latch side [§404, §703.4.2]Plus geometric symbol on the door: 12″ circle (women), 12″ triangle (men), triangle in circle (unisex), centered 58″–60″ high [11B-703.7.2.6]
☐Turning space60″ circle or T inside the room [§603.2.1]Same
☐Toilet centerline16″–18″ from the side wall [§604.2]17″–18″ [11B-604.2]
☐Toilet clearance60″ wide × 56″ deep from the rear wall [§604.3.1]Same, plus 60″ × 48″ maneuvering space in front of the toilet [11B-604.3.1]
☐Seat height17″–19″ to the top of the seat [§604.4]Same
☐Side grab bar42″ long, starting 12″ max from the rear wall, 33″–36″ high [§604.5.1, §609.4]Same
☐Rear grab bar36″ long, 12″ on one side of the toilet centerline and 24″ on the other [§604.5.2]Same
☐Flush controlOn the open side; 48″ max [§604.6, §309]44″ max [11B-604.6]
☐Toilet paper dispenser7″–9″ in front of the toilet; 15″–48″ high [§604.7]7″–9″ in front; outlet 19″ min high, below the grab bar [11B-604.7.1]
☐LavatoryRim 34″ max; knee clearance 27″ high; pipes insulated [§606]Same
☐MirrorBottom of reflecting surface 40″ max above the floor over a lavatory; 35″ max elsewhere [§603.3]Same
☐Dispensers and hand dryersOperable part 48″ max; protrude 4″ max [§308, §307]Same
☐Toilet compartment60″ wide; 56″ deep (wall-hung) or 59″ (floor-mounted); door self-closing [§604.8.1]Same dimensions; 44″ route to the compartment [11B-604.8.1]
ADA restroom with side grab bar, toilet and toilet paper dispenser in an accessible layout
Grab bars are the number one restroom finding. Height, length and position all have to be right.

5. Signage checklist

☐ItemADA requirementCalifornia (CBC 11B)
☐Permanent room signsRaised characters ⅝”–2″ high plus Grade 2 Braille; non-glare; high contrast [§703.2, §703.3]Same
☐Mounting height48″ min to the baseline of the lowest tactile character; 60″ max to the baseline of the highest [§703.4.1]Same, with an 18″ × 18″ clear floor space centered on the sign [11B-703.4.2]
☐LocationLatch side of the door [§703.4.2]Same
☐Entrance signsISA at accessible entrances when not all entrances are accessible; directional signs at inaccessible ones [§216.6]Same
☐Parking signsSee the parking section abovePlus the $250 fine and tow-away signs
ADA restroom sign mounting height measured at 48 to 60 inches on a real door
Tactile signs go on the latch side, 48″–60″ to the characters, never on the door itself.

Full detail: ADA sign requirements.

6. Everything else: drinking fountains, stairs, alarms

☐ItemADA requirementCalifornia (CBC 11B)
☐Drinking fountainsTwo heights (or one hi-lo unit): wheelchair spout 36″ max, standing spout 38″–43″; spout 15″ min from the rear support and 5″ max from the front edge [§211, §602]Same
☐Stairs on the accessible routeHandrails both sides, 34″–38″; uniform risers 4″–7″ and treads 11″ min; no open risers; nosings project 1½” max [§504, §505.4]Plus a contrasting stripe 2″–4″ wide within 1″ of the nosing: top approach and bottom tread indoors, every tread outdoors [11B-504.4.1]
☐Elevators and liftsRequired in multi-story facilities; private buildings under 3 stories or under 3,000 sq ft per story are exempt unless they are shopping centers, health care offices or transit facilities [§206.2.3]Narrower exception, and it waives only the elevator; everything else on each story must comply [11B-206.2.3]
☐Fire alarmsVisible (strobe) alarms wherever an audible fire alarm system is provided; existing systems only when upgraded or replaced [§215.1]Same
☐Employee work areasApproach, enter and exit only; common-use circulation paths accessible in areas over 1,000 sq ft [§203.9]Same
ADA drinking fountain height requirements: 36 inch wheelchair spout and 38 to 43 inch standing spout
A single fountain at one height is a finding; the Standards require a wheelchair unit and a standing unit.

California additions to the checklist

California enforces Chapter 11B of the CBC on top of the ADA, and the state version is stricter on more than 20 items. The big ones are already in the tables above: 48″ sidewalks and ramps, 44″ corridors, 108″-wide parking spaces with the $250 fine sign, 17″–18″ toilet centerlines, 44″ flush controls and geometric restroom door symbols.

Two more California items belong on any checklist:

  • Lease disclosure. Every commercial lease signed since 1 January 2017 must state whether the premises have had a CASp inspection [Civ. Code §1938]. Tenants and landlords both get sued, so responsibility for ADA compliance should be in writing.
  • CASp certificate. A property inspected by a Certified Access Specialist before a claim is served qualifies for a 90-day court stay, an early evaluation conference, and reduced minimum damages of $1,000 if violations are fixed within 60 days [Civ. Code §55.54, §55.56(g)]. Businesses with 50 or fewer employees get a 120-day window with no minimum statutory damages after a CASp inspection [§55.56(g)(3)].
California Disability Access Inspection Certificate posted after a CASp inspection
The Disability Access Inspection Certificate is what a self-check cannot give you: documented legal protection [Civ. Code §55.53(e)].

What a checklist cannot do

A checklist tells you where to look. It cannot tell you three things a CASp report does:

  • Which standard applies to each element. An element built to the 1991 Standards and never altered may be covered by the safe harbor [28 CFR 36.304(d)(2)]. A newer alteration is not. Only a dated construction history sorts that out.
  • What is readily achievable for your business. The same ramp can be required of a national chain and excused for a two-person shop [28 CFR 36.104]. The report documents the analysis.
  • Legal standing. In California, the qualified-defendant protections only attach when the inspection happened before the claim [Civ. Code §55.52(a)(8)]. A self-check has no legal weight.

Our inspectors are licensed CASp inspectors who inspect nationwide. The report lists every element measured, the finding, the citation and a correction schedule, which is also what a court expects to see [Civ. Code §55.53(a)(2)].

Want the Checklist Measured for You?

A CASp inspection turns this list into a written report with photos, citations and a fix schedule, and in California it gives you qualified-defendant protection. Call or text (949) 339-9429 for a free estimate. We inspect nationwide.

Frequently asked questions

Is there an official ADA compliance checklist?

The Department of Justice does not publish a mandatory checklist. The legal standard is the 2010 ADA Standards themselves, available on the U.S. Access Board site. The checklist above condenses those Standards into the measurements that apply to a typical business.

What is an ADA checklist for existing facilities?

It is the same list applied under the “readily achievable barrier removal” rule for buildings that predate the ADA [28 CFR 36.304]. Existing facilities must remove barriers where it is easy and inexpensive to do so, in the priority order above, and must bring any altered area up to the current Standards.

What is a CASp checklist?

A CASp inspection follows this same checklist but adds the California Building Code Chapter 11B items, documents each measurement with photos, and ends with the Disability Access Inspection Certificate. Certified Access Specialists are licensed by the California Division of the State Architect.

How often should I run through the checklist?

After any construction, after a change of tenant or use, and otherwise every few years. Exterior slopes, striping and signs degrade, and a certificate stays valid only until the site is modified in a way that affects compliance [Civ. Code §55.53(e)(3)].

Does the checklist cover websites?

No. Title III has been applied to websites by many courts, and the common standard is WCAG 2.1 Level AA, but that is a separate audit. See what ADA compliant means for how buildings, businesses and websites differ.

What happens if I fail items on the list?

Nothing automatic. There is no ADA police; enforcement comes from lawsuits and DOJ complaints. Fixing items in priority order, and documenting the plan, is both the legal expectation and the best defense.

Need a CASp inspection or ADA consultation?

Licensed CASp inspectors. Fast scheduling. Clear, court-ready reports.

CASp inspections, ADA consulting and accessibility reports for businesses and property owners across California and nationwide.

All inspectors are licensed CASp

Contact